The proportions of quantities entering wastewater treatment plants are an important criterion for the effective control of this complex system. The amount of air entering the aeration pool depends on the proportion of wastewater entering the facility. This controls the activity and effectiveness of bacteria that break down pollutants. Non-contact measurement is generally recommended to prevent contamination of the sensors from the high solid waste content in the wastewater.
Flow measurement with the MICROSON 551
Since the flow unit in the ducts changes in proportion to the level height, the MICROSON 551 ultrasonic sensor with non-contact measurement principle is the ideal solution in such specific measurement situations. Without touching the product and without the risk of contamination, the sensor can accurately measure the level and with it the instantaneous flow unit. All joint channel profiles such as Venturi, V-Notch weir are included in the sensor software and pre-programmed. Other channel profiles with properties can also be easily programmed by entering index values.
For more difficult conditions - MICROPULS 61
Radar sensors such as the MICROPULS 61 are also suitable for measuring flow rates in open channels. In chemical plants and foamy processes where the temperature of wastewater varies considerably or where solvents are present in the wastewater, a radar level sensor is especially recommended for wastewater treatment.
Advantages of MICROSON 551
|
Advantages of MICROPULS 61
|
- Maintenance-free non-contact measurement
|
- Maintenance-free non-contact measurement
|
- Turkish as menu language
|
- Turkish as menu language
|
- Easy adjustment
|
- Easy adjustment
|
- Threaded connection
|
- Special construction with IP68 protection class
|
|
- Threaded or mounting with hanging apparatus
|
MICROCON C2. F Technical Specifications
Application
|
Open Channel Flow Measurement
Flowmeters with 4...20mA and pulse output
|
|
|
Display
|
Touchscreen 4,3" TFT display
|
Data Record
|
SD card
|
Analog Input Signal
|
2 pcs. 4...20mA
|
Analog Output Signal
|
2 pcs. 4...20mA
|
Alarm Output
|
4 pcs. Relay (5A 250V)
|
Digital Input
|
1 pc. Pulse (12-30V DC)
|
Digital Output
|
2 pcs. Pulse (24V DC Max 100mA)
|
Communication
|
RS485 MODBUS
|
Supply
|
12....30V DC
|
Power Consumption
|
Maximum 6W
|
Protection Class
|
IP67
|
Cable entry
|
PG11
|
Dimensions
|
160x240x53mm
|
Material
|
ABS
|
Seal
|
Silicone
|
Temperature
|
-20...60C
|
Humidity
|
<95%
|
MICROCON C1. F Technical Specifications
Application
|
Open Channel Flow Measurement
|
|
Flowmeters with 4...20mA and pulse output
|
Display
|
Touchscreen 3,5" TFT display
|
Data Record
|
SD card
|
Analog Input Signal
|
1 pc. Standard, 1 pc. optional 4...20mA
|
Analog Output Signal
|
1 pc. Standard, 1 pc. optional 4...20mA
|
Alarm Output
|
2 pcs. Standard, 2 pcs. Optional relay (5A 250V)
|
Digital Input
|
1 pc. pulse (12-30V DC)
|
Digital Output
|
2 pcs. pulse (24V DC Max 100mA)
|
Connection
|
RS485 MODBUS
|
Supply
|
12....30V DC
|
Power Consumption
|
Max. 6W
|
Dimensions
|
144x72x65mm
|
Material
|
ABS
|
Mounting Type
|
Panel Type
|
|