Advantages
- Microwave measurement principle
- Not affected by variable product properties
- Not affected by dust and steam
- Adjustment on-screen menu or via PC
Application Areas
MICROFLEX 51 can be used for level measurement of cement, aggregate, plastic, coal, lime, mineral, feed, grain, granule and powder products and almost all liquids in metal or concrete bunkers, especially in extreme dusty silos and where necessary in chemical and solution and similar liquid tanks.
Technical Features
Measurement range
|
Rode 6 m / Rope up to 30 meters
|
Error margin
|
±10 mm
|
Process connection
|
Thread G11/2 / Flange from DN 50 up
|
Process pressure
|
-1 … 40 bar
|
Process temperature
|
-40...150 °C
|
Electronic
|
4...20mA / HART
|
Operating voltage
|
14… 36 V DC (Optional 220V AC)
|